Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
International Eye Science ; (12): 887-893, 2023.
Article in Chinese | WPRIM | ID: wpr-973771

ABSTRACT

AIM:To compare refractive and safety outcome of Artisan and Artiflex phakic intraocular lens(PIOL)for the correction of high myopia in Asian population.METHODS:Historical cohort study. A total of 81 high myopic eyes that underwent PIOL implantation from 2016 to 2020 at Yap Eye Hospital in Yogyakarta, Indonesia were reviewed. The patients were divided into two groups based on PIOL implanted, with 43 eyes using Artisan PIOL in Artisan group and 38 eyes using Artiflex PIOL in Artiflex group. Visual acuity, corneal biomicroscopy parameters, and intraocular pressure(IOP)were respectively recorded prior to the implantation and at 1d, 1 and 3mo after surgery. In addition, anterior chamber depth was documented before PIOL implantation.RESULTS:Mean follow-up period were 9.64±6.93mo and 8.96±4.28mo in Artisan an Artiflex group, respectively(P=0.736). The efficacy index was 1.03±0.47 in Artisan group, and 1.02±0.17 in the Artiflex group(P=0.119).The safety index was 1.10±0.45 and 1.05±0.21 in Artisan and Artiflex group, respectively(P<0.001). The mean spherical equivalent(SE)in Artisan group was -0.64±0.996D, and it was -0.22±0.58D in Artiflex group(P=0.076). In both groups, there was a significant loss of endothelial cell density(ECD)postoperatively compare to baseline(P<0.05), and the cumulative ECD loss was 7.44% and 5.79% in the Artisan and Artiflex groups, respectively(P=0.418).CONCLUSION:Artisan and Artiflex are comparable in terms of refractive outcome to correct high myopia in Asian eyes. Artisan had a slightly better safety index compare to Artiflex. However, the efficacy index and cumulative ECD loss was similar in both the Artisan and Artiflex groups.

2.
Article | IMSEAR | ID: sea-218409

ABSTRACT

Aims: In this study, we aimed to investigate the intercorrelations between tear film break up time, measured non-invasively using non-invasive keratographic break-up time (NIKBUT), higher order aberrations (HOA) and quality of vision (QoV) in pseudophakic patients.Study Design: Cross-sectional.Methods: Thirty-five pseudophakic aged patients aged 50 years or older, and 35 control phakic patients aged 17 to 23 years with corrected visual acuity of 20/20 were included in this study. All subjects underwent similar examination including QoV questionnaire, aberrometry to measure HOA, and NIKBUT. HOA was measured with the OPD-Scan/ ARK 10000 corneal analyzer (Nidek CO. Ltd), expressed as Root Mean Square (RMS) HOA and NIKBUT was assessed using non-invasive TF-Scan module Keratograph 5M (K5M), equipped with modified tear film scanning function (Oculus, Wetzlar, Germany). Statistical analysis was performed to find the correlation between NIKBUT, HOA and QoV.Results: Patients in the pseudophakic group were significantly older (median age 66 vs. 20 years; P<0.01), had shorter NIKBUT (10.5 vs. 17.2; P<0.01), lower QoV score (1.63 vs. 0.68; P=0.04), and higher RMS HOA (0.5 vs. 0.26; P<0.01) compared to control group. NIKBUT was inversely correlated with RMS HOA (r = -0.19; p = 0.03) and RMS HOA was significantly correlated with QoV, even after adjustment for age and gender (r = -0.21; P0.04). NIKBUT <9.93s was correlated with lower QoV. The area under the curve was 0.81 (95% CI = 0.67 � 0.95, p = 0.012), and had 100% sensitivity and 61% specificity.Conclusion: Shorter NIKBUT was correlated with greater HOA and greater HOA was correlated with lower QoV. NIKBUT value of shorter than 9.93s could potentially predict pseudophakic patients who will likely experience visual symptoms leading to decreased QoV; thus, the use of artificial tears might be beneficial.

3.
Article | IMSEAR | ID: sea-218415

ABSTRACT

Aims: Image-guided systems are the gold standard for determining toric intraocular lens (IOL) axis alignment. However, their high cost prevents widespread use of these systems. As an alternative, a simpler and affordable method could be performed manually using a slit-lamp biomicroscope. This study aims to compare the accuracy of manual toric IOL axis marking using a slit-lamp compared to the CALLISTO eye image-guided system.Study Design: Prospective comparativeMethods: In this prospective study, toric IOL axis alignment of 42 eyes with cataract and coexisting corneal astigmatism were evaluated using manual slitlamp method and CALLISTO eye image-guided method. Preoperative and postoperative uncorrected visual acuity, best corrected visual acuity, amount of spherical and astigmatic refractive errors, and postoperative IOL axis alignment were evaluated. Intraclass correlation of the manual method was calculated and the difference of IOL axis alignment to the image-guided method was compared.Results: Toric IOL implantation reduced the amount of astigmatic refractive error from -1.63 � 0.65 D to -0.50 � 0.19 D in the image-guided group and from -1.93 � -0.90 D to -0.87 � 0.26 D in the manual slitlamp group. As many as 90.5% of eyes in the image-guided group and 81.0% of eyes in the manual slitlamp group reached the target induced astigmatism (p=0.38). Manual axis marking showed intraclass correlation of 99.3%. However, when the manual method was compared to the image-guided method a mean difference in axis alignment of 10.98o (95% confidence interval: 9.32o - 12.63o) was observed.Conclusions: Alignment of toric IOL axis using the manual method demonstrated a consistent result; yet producing a considerable difference to the result of the image-guided method.

4.
Imaging Science in Dentistry ; : 261-268, 2018.
Article in English | WPRIM | ID: wpr-740393

ABSTRACT

PURPOSE: To determine the impact of an image processing technique on diagnostic accuracy of digital panoramic radiographs for the assessment of anatomical structures in paediatric patients with mixed dentition. MATERIALS AND METHODS: The study consisted of 50 digital panoramic radiographs of children aged from 6 to 12 years, which were later on processed using a dedicated image processing method. A modified clinical image quality evaluation chart was used to evaluate the diagnostic accuracy of anatomical structures in maxillary and mandibular anterior and maxillary premolar region of processed images. RESULTS: A statistically significant difference was observed between pre and post-processed evaluation of anatomical structures (P 0.05). The Inter-observer and intra-observer reliability of both pre and post processed images were excellent (>0.82) for anterior region and good (>0.63) for premolar region. CONCLUSION: The application of image processing technique in digital panoramic radiography can be considered a reliable method for improving the quality of anatomical structures in paediatric patients with mixed dentition.


Subject(s)
Child , Humans , Bicuspid , Dentition, Mixed , Diagnosis , Methods , Radiography , Radiography, Panoramic
5.
Southeast Asian J Trop Med Public Health ; 2003 Jun; 34(2): 291-7
Article in English | IMSEAR | ID: sea-35807

ABSTRACT

Toxoplasmosis was the most common cause of primary retinochoroiditis. The majority of cases of ocular toxoplasmosis were congenital. However, cases of acquired ocular toxoplasmosis have been reported. The clinical manifestations of congenital ocular toxoplasmosis were choroidal coloboma, strabismus, nystagmus, ptosis, microphthalmia, cataract and enophthalmia. The purpose of this study was to determine the clinical presentation and visual outcome of 173 patients with ocular toxoplasmosis at Dr Sardjito Hospital, Dr Yap Eye Hospital, and private practice during the last six years. A total of 173 subjects were studied--98 males and 75 females. The ages at which first diagnosis was established ranged from 3 months to 68 years, frequently in young adults and occurring mostly in students. The most-reported chief complaint was blurred vision in 70.5% and floaters in 6.1% of cases. The most frequent clinical manifestations were chorioretinitis (71.2%), macular scars (22.4%), squint (6.4%), congenital cataract (2.8%), nystagmus (6.4%) and atrophic optic papilla (2.8%). Bilateral involvement was found in 32.4% of all patients. The therapeutic outcome showed improvement, especially visual acuity in acute cases (25.6%). However, visual acuity categorized as blindness was 13.9%. The results of the study imply that suddenly blurred vision in the quiet eye in the young adult, squint, and nystagmus in children could be chorioretinal inflammation and scar caused by Toxoplasma gondii.


Subject(s)
Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Indonesia/epidemiology , Infant , Male , Middle Aged , Toxoplasmosis, Ocular/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL